Increased Piping Length for Greater Design Flexibility. Adaptable to various building types and sizes. Actual piping length: 200 m. Maximum piping length: 1,000 m. *1: 40 m if the outdoor unit is below the indoor unit. An elevation difference of a maximum 90 m in the case of ODU is higher than IDU may be allowed following certain conditions. Air Conditioner Pair Coil/Copper Pipe Sizing Chat for Split System. January 13, 2023 by starsparky direct. Please seek professionals for Air Conditioning installation. Please do not DIY. There are 5 common sizes of copper pipes. See tablel: Ø Diameter (in i nches) Ø Diameter (in mm) 1/4''.
I use to have a pdf for easy reference that I cannot find right now but; E9JKR = 1/4-3/8 inch. E12JKR-E21JKR = 1/4-1/2 inch. E24JKR-E28JKR = 1/5-5/8 inch. W7DKR-W9DKR = 1/4-3/8 inch. W12EKR-W18DKR = 1/4-1/2 inch. W24EKR = 1/4-5/8 inch. All ducted up to 14kW = 3/8-5/8 inch.
Features: Includes Nanoe X air purification technology. Outstanding operating range. Cold draft reduction technology. 16kW Cooling - 18kW Heating Capacity. Panasonic High Static Ducted System 16kW. Indoor: S-160PE3R. Outdoor: U-160PZH2R5 | Single Phase R32. Includes CZ-RTC5B Wired Controller.
What are the pipe sizes? Asked by james on 06/26/2012 1 Answer. ManualsOnline posted an answer 11 years, 5 months ago. The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here.
W i-Fi Function, Supported with Panasonic Comfort Cloud App (Read More) Environmental Friendly R32 Refrigerant. Product Specification. 1.5 HP (Heatpump Model - With Remote Control) Cooling Capacity:11,900 Btu/h. Heating Capacity: 13,600 Btu/h. Grade 1 Energy Label. Warranty. 1 year warranty: Entire unit.
Specifications Features Brochure Description Reviews CS/CU-Z71XKR Panasonic 7.1kW Z Series Reverse Cycle Split System Air Conditioner R32 | Advance Air Purification System | Nanoe™X
Refrigerant Pipe Diameter Liquid Side (mm) ø 6.35: Liquid Side (inch) 1/4: Gas Side (mm) ø 15.88: Gas Side (inch) 5/8: Pipe Extension Chargeless Pipe Length (m) 10: Maximum Pipe Length (m) 20: Maximum Elevation Length (m) 15: Additional Refrigerant Gas* (g/m) 20: Power Supply: Indoor: Cleaner Air nanoe-G: Yes: Anti-Bacterial Filter: No: Odour